FMVSS 302: Federal Motor Vehicle Safety Standard 302
FMVSS302 Flammability of Interior materials

FMVSS 302 Scope£º
This standard specifies burn resistance requirements for materials used in the occupant co***rtments of motor vehicles

FMVSS 302 Purpose.£º

The purpose of this standard is to reduce the deaths and injuries to motor vehicle occupants caused by vehicle fires, especially those originating in the interior of the vehicle from sources such as matches or cigarettes.

FMVSS 302 Application£º

This standard applies to passenger cars, multipurpose passenger vehicles, trucks, and buses.

FMVSS 302 Test Procedure£º

a. Mount the specimen so that both sides and one end are held by the U-shaped frame, and one end is even with the open end of the frame. Where the maximum available width of a specimen is not more than 51 mm, so that the sides of the specimen cannot be held in the U-shaped frame, place the specimen in position on wire supports as described in S5.1.3, with one end held by the closed end of the U-shaped frame.
b. Place the mounted specimen in a horizontal position, in the center of the cabinet.
c. With the flame adjusted according to S5.1.4, position the bunsen burner and specimen so that the center of the burner tip is 19 mm below the center of the bottom edge of the open end of the specimen.
d. Expose the specimen to the flame for 15 seconds.
e. Begin timing (without reference to the period of application of the burner flame) when the flame from the burning specimen reaches a point 38 mm from the open end of the specimen.
f. Measure the time that it takes the flame to progress to a point 38 mm from the clamped end of the specimen. If the flame does not reach the specified end point, time its progress to the point where flaming stops.
g. Calculate the burn rate from the formula: B = 60 ¡Á (D/T)
Whe

Contact Us
Company: CASfire Technical Co.,Ltd
Contact: Mr. Ziteng Liu
Address: 8F Building 4, Chinese Academy of Sciences, No.255 South Duiying Road, Jimei Xiamen 361021, China
Postcode:
Tel: 0592-3500085
Fax: 0592-3500085
E-mail:         


Copyright© CASfire Technical Co.,Ltd All Rights Reserved.
Tel : 0592-3500085 Fax : 0592-3500085
Powered by 86exporter.com